Gas Concentration Units and Unit Conversions

Condensed from an OPSIS AB article by Bengt Löfstedt, first published 2023-05-11.

In brief
  • Mass concentration depends on the volume, and volume depends on temperature and pressure.
  • Industry normalises to 0 °C and 1 atm; air quality uses 20 °C in Europe and 25 °C in the US.
  • mg/m³ and ppm convert through molecular mass and molar volume, so the factor differs per gas.

Summary

Converting molecule count into a mass concentration is straightforward in principle: one molecule of a given gas always weighs the same, and in practice you calibrate the instrument against a standard gas of known concentration rather than counting molecules. The subtlety is the volume, because the same number of molecules occupies different volumes at different temperatures and pressures. In-situ instruments measure where the molecules actually are, so the question does not arise; extractive instruments measure in a cell whose temperature and pressure generally differ from those at the sampling point. The convention is therefore to normalise the volume to a standard state — in industry almost always 0 °C and 1 atm, in air quality 20 °C in Europe and 25 °C in the United States — giving what is called a normalised or standard volume. Industrial mass concentrations are usually quoted in mg/m³ or g/m³, ambient ones in µg/m³. Volume concentrations in ppm or ppb follow from molecular mass and molar volume, and only from those.

A.Johnson note

In China the same normalisation logic runs through the emission monitoring system: CEMS data are reported at standard state, 273.15 K and 101.325 kPa, on a dry basis and referenced to the oxygen level that the industry standard requires, while ambient air quality under GB 3095 is assessed at actual temperature and pressure in µg/m³. Those are two different bases, and comparing across them without care produces wrong conclusions. Before quoting or comparing a concentration we check three things: the basis — which temperature, dry or wet, oxygen-corrected or not; the conversion factor — it follows the molecular weight, so SO2 and NO2 cannot share one; and the unit of the calibration gas, since many instruments are calibrated in ppm and report in mg/m³. For international work, note that EU and US ambient systems use 20 °C and 25 °C while industrial emissions use 0 °C, so the basis should be stated on the cover of any data package that crosses systems.

The original article

Gas Concentration Units and Unit Conversions — read the original at opsis.se ↗

Written by Bengt Löfstedt, OPSIS AB, first published 2023-05-11. The summary and the A.Johnson note above are our own text; the OPSIS article remains the authoritative version. Chinese reader? See the full Chinese article.

Related

Discuss your application

Send the gases, ranges, duct or path dimensions and required certification — we will respond with a technical proposal.

+86-21-52361751info@ajopsis.com