DX100 dioxin and CO₂ sampler

Long-term isokinetic sampling that represents average emissions, not a short snapshot.

Dioxin emissions fluctuate. A short manual sample can miss the peaks, while a one to four week isokinetic sample averages them. DX100 collects PCDD/Fs on XAD-2 with flow-proportional CO₂ sampling.

Method

The probe tracks duct velocity to maintain isokinetic conditions. Sample gas passes through XAD-2 adsorbent, and a proportional CO₂ sample is taken at the same time so the result can be normalised and used for emission factor work.

Technical data

Sampling methodIsokinetic sampling + XAD-2 adsorption
Sampling period1–4 weeks continuous
Target compoundsPCDD/Fs and CO₂
StandardsEN 1948 · HJ 77 · MCERTS

Typical data from OPSIS product documentation; specifications depend on the application and are confirmed at quotation stage.

Frequently asked questions

Why sample over one to four weeks?

Long-term sampling averages normal operating fluctuations, which is more representative of actual emissions than a short manual sample.